Overview

The automatic control for the molten steel level of the mold is one of the key technologies of continuous casting production. It is very important to reduce the labor intensity of workers, improve production efficiency, improve the quality and output of casting billet, reduce overflow and breakout of steel and improve the management level of steelmaking and continuous casting.

The molten steel is poured into the mold. In order to prevent overflow, the molten steel level must be kept stable. Otherwise, during the casting process, if the level will fluctuate too much, and slag will be involved, forming surface slag inclusion on the surface of the casting billet, affecting the quality of the billet. The test points out that the relationship between the level fluctuation and the depth of casting billet surface slag inclusion is as follows:

The experience has shown that surface slag inclusions can be eliminated when the level fluctuation is within ±10mm. At the same time, if the level fluctuation is more than 10mm, the rate of longitudinal cracks on the casting billet surface is 30%. It means that the level fluctuation directly affects the surface quality of the casting billet.




The principle of the system

The eddy current type molten steel level gauge is the key to the system. The system operates reliably and has excellent performance: high temperature resistance, strong anti-interference ability, fast dynamic response (lag time <0.10s), high detection accuracy (<±05mm), and large measurement range (0-150mm). The selected electromagnetic field frequency ensures that the level detection probe only detects the level change of the mold and does not detect the mold flux or steel slag layer. The system has the advantages of simple operation and no radiation protection problems. The system is insensitive to argon blowing, and its sensors can be mounted on the tundish car or on the platform.



The components of the system

Continuous casting mold level automatic control system is composed of eddy current tyoe molten steel level gauge, controller and digital actuator for adjusting the opening of tundish stopper.

The detection end of the mold level automatic control system is ① eddy current displacement sensor, which uses the eddy current mutual inductance effect between the energized coil and the metal conductor to detect the distance. The effective signal of the eddy current sensor is amplified and linearized by the circuit of ② mold level gauge, which converts the 0-150mm change in the molten steel level of the mold into a standard signal of 4-20mA.DC, and then transmits it to the ③ control computer to complete data processing and system control functions. We can also control the actuator manually and automatically through the ④on-site operation display control panel, and the opening of the stopper is controlled by the ⑤ actuator to realize the automatic control of the molten steel level.

1 Eddy current sensor;

2 mold level gauge;

3 control computer;

4 On-site operation display control panel;

5 digital actuator;



The control principle of the system

The system can be set to four control modes: automatic, semi-automatic, manual and motor clutch. The automatic mode is the closed-loop control system of the molten steel level, and control the opening of the stopper by the digital actuator; the semi-automatic mode uses opening degree setter and digital actuator to set the opening of the stopper manually; the manual mode is to open and close the button directly to control the opening of the stopper; the motor clutch mode is quickly changed from any of the above control methods to manual stopper operation.

The functions of the system also include: display and record of molten steel level, nozzle opening and casting speed; setting of molten steel level and nozzle opening; alarm of molten steel level at limit value etc.

In addition to taking the detection of molten steel level as the main feedback signal of the control system, the control system also considers various interference factors that have an impact on the level control. These interference factors include:

1. The influence of the change of the flow characteristics on the control system after the melt loss of the stopper

2. The influence of the weight change of molten steel in the tundish on the control system

3. The influence of the change of the casting speed of the continuous casting machine on the control system

4. The influence of the mold width change (the mold width is adjustable) on the control system

5. The influence of the vibration frequency and amplitude of the mold on the molten steel level gauge

Wuhan CenterRise M&C Engineering CO., Ltd.
more info, please contact
Mobile: +86 13995588597
whatsapp:+86 15727288019
sales@whzfy.com
Website:whzfy18.com
ADD:Wuhan, Hubei, China

Attributes

Condition: New
Transaction: Sell
Start chatting
User is offline
Start chatting
User is online

Floria Liang's profile

Floria Liang
Floria Liang Registered for 9+ months Last online 9 months ago
Seller's description No description left by seller

Contact Floria Liang (seller)

    You must log in or register a new account in order to contact the advertiser.
    To protect against prohibited activities, we may check your message before it is forwarded to the recipient and, if necessary, block it.

    Other items from this seller

    Seller details Details

    Floria Liang
    Floria Liang
    25 active listings
    Non-Professional seller
    Registered for 9+ months
    Last online 9 months ago
    Chat unavailableStart chat Contact All items

    Listing location

    Unknown location

    Stay safe!

    Never pay down a deposit in a bank account until you have met the seller, seen signed a purchase agreement. No serious private advertisers ask for a down payment before you meet. Receiving an email with an in-scanned ID does not mean that you have identified the sender. You do this on the spot, when you sign a purchase agreement.
    MLC-V235 Continuous Casting Mold Level Control System MLC-V235 Continuous Casting Mold Level Control System MLC-V235 Continuous Casting Mold Level Control System MLC-V235 Continuous Casting Mold Level Control System
    $200,000 MLC-V235 Continuous Casting Mold Level Control System by Floria Liang